【May 6 and 7】Hands on training session for spinning disk confocal microscope system Andor Dragonfly

This is to inform you of the Hands-on training session (by Toshiyuki Watanabe, Andor Technology) for Andor Dragonfly running in iCeMS Analysis Center, which was allocated based on the activity of MaCBES.

Dragonfly offers high-speed (up to 400 fps) spinning disk confocal observation with reduced pinhole crosstalk and high full-field uniformity. The microscope system enables high contrast 3D observation for large volume samples as well as for subcellular dynamics imaging. For details, please visit
https://andor.oxinst.com/products/dragonfly.
The specification of the system in iCeMS Analysis Center is summarized at the bottom.

The session is intended for the researchers
(1) who plan to start using the microscope in the coming 2 months, and
(2) who can bring own sample.
In addition, for infection control of COVID-19,
(3) Only one person is allowed for one session.

[Schedule]
May 6 (Thu): 3 sessions in the afternoon
May 7 (Fri): 1 session in the morning and 3 sessions in the afternoon
1.5 hrs each (operation training using own sample)

We appreciate your cooperation on the training day:
1. Please keep wearing a mask.
2. Fill in the list at the entrance door with your name, affiliation, and enter/exit time.
3. Disinfect fingers by 70% alcohol before entering the room.
4. Keep the room door open to avoid staying in an enclosed space.

[Place]
Room 302 of Research Bldg. No.1 Annex (#33 building of Main Campus)
https://www.kyoto-u.ac.jp/en/access/main-campus-map.html
iCeMS Analysis Center, iCeMS, KUIAS, Kyoto University

[Language]
Japanese or English

For registration and assignment of the slot, please contact Takahiro Fujiwara (tfujiwara[at]icems.kyoto-u.ac.jp) of iCeMS Analysis Center by April 27 (Tue). Please understand that we will not be able to accept all applicants due to the limited time slots, and the session might be postponed depending on the situation of COVID-19.

Best regards,
Takahiro Fujiwara, iCeMS Analysis Center

———————————————————-
[仕様/Specification]

Multimodal Fast Confocal Microscope System Andor Dragonfly
・Dragonfly 502
Spinning disk with 2 pinhole diameters (25 and 40 microns), Borealis illumination, Laser-illuminated widefield mode, 2 camera ports, Camera magnification (3-position motorized), Illumination zoom, GPU-accelerated deconvolution in parallel with acquisition, Imaris Core
・Motorized inverted microscope Nikon Ti2-E
・Lasers
405 nm/100 mW, 488 nm/150 mW, 561 nm/100 mW, 637 nm/140 mW
・Cameras
iXon Ultra EMCCD
Zyla 4.2 Plus sCMOS
・Automatic focus correction unit (Perfect Focus)
・ASI motorized XY stage and stage piezo (500-micron range)
・Objectives
CFI Plan Apochromat Lambda 10X Dry NA 0.45 WD 4.00
CFI Plan Fluor 20X MImm (Oil/Glycerin/Water) NA 0.75 WD 0.35-0.33
CFI Plan Apochromat Lambda S 40X Silicone NA 1.25 WD 0.30
CFI Plan Apochromat VC 60XC Water NA 1.20 WD 0.31-0.28
CFI Apochromat TIRF 60XC Oil NA 1.49 WD 0.13-0.07
CFI Plan Apo Lambda 60X Oil NA 1.40 WD 0.13
CFI Plan Apo VC 100X Oil NA 1.40 WD 0.13
・Tokai Hit stage top incubator
・Mosaic3 photostimulation unit with 405 nm/450 mW laser